Jan 09, 2019 Leave a message

Precautions for rolling force sensor calibration

4 Precautions for rolling force sensor calibration

(1) Due to the strong overload capability of the rolling force sensor and the speciality of recalibration after rework, whether it is a resistive strain gauge rolling force sensor or a magnetoelastic rolling force sensor, it is generally 120% of the design load. Preloading, overload preloading can also help the rolling force sensor reach the actual zero point at a faster working condition.

(2) The resistance range of the resistive strain-type rolling force sensor is generally in the range of (1.5~2.0) mV/V. If the full-scale sensitivity output value is less than 1.5mV/V during the preloading process, it can basically be preliminary. It is considered that the sensor elastomer overload is severe to performance damage, and the possibility of repair is relatively small. This can also be obtained from the straightness and hysteresis of the sensor, which is usually far better than the performance index requirement of 1.0% FS, and the repeatability is not good. The result is obtained.

(3) The magnetoelastic rolling force sensor can adjust the output resistance value in the control circuit according to the value indicated by the force value display during the preload phase, and can adjust the output force value, even according to customer requirements. The force point is adjusted to ensure that the force value achieves a substantially zero error between the displayed value and the standard value.

It should be noted that the force value adjustment is not adjusted once, and needs to be adjusted several times in steps. The steps to adjust the force value are as follows:

1) After the overload preload is completed, the force value display meter is cleared, and then directly loaded to the full-scale load force value of the rolling sensor. At this time, the circuit resistance value is roughly adjusted, and the display force value is adjusted to the standard force value. In the vicinity, the standard machine force value is unloaded to zero, and the zero point value of the tested rolling force sensor is observed.

2) Record the zero point value of the rolling force sensor and clear the zero point force value. The control force standard machine loads the force value to the full scale step by step, and records the display value of the sensor force value meter of each level during the loading process, combined with the sensor zero point value. And the calibration point indication value, analysis determines the direction and size of the resistance resistance adjustment, and performs the second circuit resistance adjustment. After the resistance adjustment, the force value needs to be unloaded to zero.

3) After the zero value of the sensor is recorded, it is cleared, and the control force standard machine is loaded to the full scale again step by step to verify whether the resistance adjustment scheme is correct.

4) If the expected result is achieved, the formal calibration measurement process can be started. If there is still a certain discrepancy with the expected result, repeat the steps of 3.2 resistance adjustment again until the requirements are met.

(4) Due to the special structure of the magnetoelastic rolling force sensor, the locking torque value of the side fixing bolt of the sensor can affect the linearity of the sensor to a large extent, and usually requires the magnetoelastic load cell to be repaired after completion. Use a set torque wrench to lock each bolt to the standard torque value.

(5) After the calibration is completed, according to different types of rolling force sensors, relevant parameters, such as resistive strain-type rolling force sensors, need to measure their input resistance, output resistance, resistance of each bridge arm, etc.; The magnetoelastic rolling force sensor needs to measure its output resistance. Usually, the rolling force sensor also needs to measure the insulation resistance to check whether it meets the requirements.