Mar 05, 2019 Leave a message

Squirrel Cage Rotor Failure Check

Squirrel cage rotor failure check

1 Causes and consequences of squirrel cage rotor failure

The squirrel-cage rotor is divided into a copper strip rotor and a cast aluminum rotor. Among them, the cast aluminum rotor is used more. Therefore, the cast aluminum rotor is taken as an example here. Common faults in cast aluminum rotors are broken cages, including broken strips (one or several fractures in the cage, or severe air bubbles) and broken rings (one or several splits in the end ring). The reasons for this include the following two aspects:

1 cast aluminum rotor manufacturing quality is poor, poor structural design, causing shrinkage, blisters, interlayers and other problems, the motor runs slowly for a long time.

2 Poor use conditions or improper use, such as frequent start-up, frequent reversal, overload, etc., so that the rotor winding current is too large, resulting in high temperatures, resulting in broken bars. After the rotor fails, the ability of the motor with load is significantly reduced, the speed is reduced, the three-phase current of the stator winding is unbalanced, and it is accompanied by a periodic "click" sound. Under normal circumstances, when the total number of rotor bar breaks accounts for 117 of the total number of slots of the rotor, the motor cannot operate normally, and the no-load start is difficult, and the load may suddenly stop.

2 squirrel cage rotor failure check

There are many methods for checking the squirrel-cage rotor failure. The following two types are commonly used.

(1) Direct observation by the naked eye

For staff with operational experience, direct observation can be used for judgment. First disassemble the motor, pull out the rotor, and carefully check the surface of the rotor core, especially at the junction of the end ring and the bar. If cracks or overheating or discoloration are found, it is the fault of the circuit breaker.

(2) Using ammeter detection

An AC voltage having a voltage value of approximately 10% of the rated voltage is applied to the stator windings by means of a voltage regulator. Slowly turn the rotor by hand and measure the stator three-phase current with an ammeter. If the rotor winding is normal, the three-phase current of the stator is basically stable and only slightly oscillated; if the rotor is broken, the ammeter pointer will produce a large amplitude periodic oscillation. This method is simple and easy, but the sensitivity is not high, and sometimes the motor can be misjudged due to uneven air gap and magnetic circuit asymmetry, and the fault point cannot be accurately found.