Some analysis of servo motor failure

Seven, the motor is difficult to start, rated load.

Motor speed is lower than rated speed

1, the cause of the failure

1 power supply voltage is too low;

2-sided connection motor misconnection;

3 rotor is welded or broken;

4 The rotor local coil is misconnected and reversed, and the number of turns is increased when repairing the motor winding.

5 Motor overload.

2, troubleshooting

1 measure the power supply voltage and try to improve it;

2 correct the connection;

3 check the welding and breakpoints and repair;

4 Check the misconnections and correct them;

5 restore the correct number of turns;

6 load shedding.

Eight, the motor is overheated and even smokes

1, the cause of the failure

1 power supply voltage is too high;

2 The power supply voltage is too low, the motor is operated with the rated load, and the current is too large to make the winding heat;

3 When repairing and removing the winding, use the thermal disassembly method improperly to burn the iron core;

4 motor overload or frequent start;

5 motor phase loss, two phases running;

6 Rewinding is not sufficient for the winding immersion paint;

7 Ambient temperature is high. The motor surface has a lot of dirt, or the air duct is blocked.

2, troubleshooting

1 reduce the power supply voltage (such as adjusting the power transformer tap);

2 increase the power supply voltage or change the thick power supply wire;

3 overhaul the iron core to eliminate the fault;

4 load shedding; control start according to the specified number of times;

5 resume three-phase operation;

6 using secondary dipping paint and vacuum dipping process;

7 Clean the motor, improve the ambient temperature, and adopt cooling measures.

Nine, the motor vibration is large during operation

1, the cause of the failure

1 due to excessive wear bearing clearance;

2 air gap is not uniform;

3 rotor imbalance;

4 shaft bending;

5 Coupling (pulley) coaxiality is too low.

2, troubleshooting

1 overhaul the bearing and replace if necessary;

2 adjust the air gap to make it uniform;

3 correct rotor dynamic balance;

4 straight shafts;

5 Recalibrate to make it compliant.

Ten, bearing overheating

1, the cause of the failure

1 too much or too little grease;

2 oil quality is not good with impurities;

3 The bearing is not properly matched with the journal or end cap (too loose or too tight);

4 bearing inner hole eccentric, rubbing with the shaft;

5 motor end cover or bearing cover is not flat;

6 The motor and load coupling is not corrected, or the belt is too tight;

7 bearing clearance is too large or too small;

8 The motor shaft is bent.

2. Troubleshooting

1 add grease according to the regulations (1/3-2/3 of the volume);

2 replace the clean lubricating grease;

3 over-loose can be repaired with adhesive, over-tightening the car, grinding the journal or the inner hole of the end cap to make it suitable;

4 Repair the bearing cover to eliminate the rubbing point; please pay attention to the micro-signal technology training for more exciting content;

5 re-assembly;

6 recalibrate and adjust the belt tension;

7 replace the new bearing;

8 Correct the motor shaft or replace the rotor.

Mikkeli AGV can carry out material handling tasks efficiently, accurately and flexibly, and multiple AGVs can form a flexible logistics handling system that can be adjusted in time with the adjustment of the production process, enabling a production line to produce ten Several products have increased the flexibility of production and the competitiveness of enterprises. The Mi Ke Li Mei AGV is a good choice for your automatic handling!