Motor mech suppliers, the composition of motor energy loss:
(1) Copper loss: stator copper loss; rotor copper loss; stray loss. (2) Core loss. (3) Mechanical loss: ventilation loss; friction loss. Judging from the energy loss of asynchronous motors listed above, copper loss and iron loss are not easy to change in our overhaul. They are determined by design, and mechanical loss can be changed. Generally speaking, asynchronous motors with a small number of stages, that is, a motor with a high number of revolutions, have greater mechanical loss and less copper loss; and a motor with a larger number of stages, that is, a low number of revolutions, accounts for a larger proportion of copper loss than the mechanical loss. Therefore, if we want to reduce the energy loss of the motor, we must start with reducing the mechanical loss of the motor.
When the motor is at no load or light load, the total loss of the motor is smaller than the rated time, and the air volume is proportional to the total loss of the motor, so the fan is in a "big horse-drawn cart" (because the ventilation loss is constant with the motor speed, the ventilation loss It does not change with the load, so the air volume should be reduced at this time to reduce the ventilation loss of the motor). Changing the shape of the fan blades can reduce the air volume, but it is more troublesome. It is easier to reduce the air volume by directly reducing the diameter of the outer fan blades. We know that the mechanical loss of the fan itself is proportional to the 4-5th power of the fan blade diameter, and the air volume is proportional to the square of the fan blade diameter. Therefore, when the fan blade diameter is reduced, the air volume is not reduced much, but the ventilation loss is reduced a lot.