China 230v ac motor factory, direct sales quality assurance
First of all, I have determined that China 230v ac motor factory, the quality of the production of the motor is guaranteed! But do not ensure that there will be noise problems during the application, then now the AC motor noise analysis.
The noise of the AC motor indicates that there is a fault inside the machine. Different sounds indicate that the fault location is different. We can use this to make judgments and avoid blind maintenance.
1. The wiring of the first end of the AC motor stator winding is wrong, there is a low hum and the speed is also reduced.
2. When the stator rubs against the rotor, it will produce a harsh "click" rubbing sound, which is caused by the bearing obstacle. Bearings should be inspected for damage and updates. If the bearing is not broken and the bearing is found to be in the inner or outer ring, the sleeve and the end cap can be replaced or replaced.
3. When the AC motor bearing is seriously deficient in oil, a “click” sound can be heard from the bearing chamber. The bearings should be cleaned and new oil added.
4. The AC motor is running out of phase and the hum is particularly loud. It can be turned off and then closed to see if it can start normally. If it can't start, there may be a phase fuse open circuit. Phase loss operation can also occur when the switch and contactor contacts are not connected.
5. When the cage rotor bar is broken or the wound rotor winding joint is disconnected, sometimes the high and low "beep" sound, the rotation speed is also slow, and the current is increased, and the inspection should be checked. In addition, some AC motor rotors and stators have poor length matching. For example, the stator length is much longer than the rotor length, or the end cover bearing holes are worn too much, and the rotor generates axial turbulence, which also produces a "click" sound.
6. The wind leaves hit the shell or have debris, making a sound of impact. The blades should be calibrated to remove debris from the blades.
The AC motor has stable performance and strong flexibility. When noise occurs, it should be processed in time to analyze and solve the problem.