Jan 25, 2019 Leave a message

Analysis Of The Cause Of Servo Motor Failure (7)

Analysis of the cause of servo motor failure (7)

Ten, the motor is overheated and even smokes

1. Reason for failure:

1 power supply voltage is too high;

2 The power supply voltage is too low, the motor is operated with the rated load, and the current is too large to make the winding heat;

3 When repairing and removing the winding, it is not appropriate to use the hot-breaking method to burn the iron core;

4 motor overload or frequent start;

5 motor is out of phase, two phases are running;

6 rewinding is not sufficient for the winding dipping paint;

7 high ambient temperature, the motor has more dust on the surface, or the air duct is blocked;

2. Troubleshooting:

1 lower the power supply voltage (such as adjusting the power transformer tap);

2 increase the power supply voltage or change the thick power supply wire;

3 overhaul the iron core to eliminate the fault;

4 load shedding; control the start according to the number of rules;

5 resume three-phase operation;

6Select secondary dipping paint and vacuum dipping process;

7 Clean the motor, improve the ambient temperature, and choose the cooling method.