Analysis Of The Cause Of Servo Motor Failure (5)

Analysis of the cause of servo motor failure (5)

Eight, the motor does not turn after the power is turned on.

1. Cause of failure

1 The rotor winding has an open circuit (one phase disconnection) or the power supply loses phase;

2 The winding lead wire is connected to the wrong end or the inner winding is reversed;

3 power circuit contacts are loose, touch resistance is large;

4 the motor load is too large or the rotor is stuck;

5 power supply voltage is too low;

6 small motor installation is too tight or the grease inside the bearing is too hard;

7 bearings are stuck.

2. Troubleshooting

1 to identify the breakpoint to be amended;

2 Check the winding polarity; determine whether the winding end is correct;

3 Fasten the loose connecting screws and use a multimeter to judge whether the joints are falsely connected and correct them;

4loading or detecting and eliminating mechanical failure,

5 Check if the ruled face connection method is misconnected; if the power supply wire is too thin to make the pressure drop too large, correct it.

6 from the beginning to make it flexible; replace qualified grease;

7 Correct the bearing.