Thermal power unit remote thermal load real-time online monitoring solution

Features

DIT-SCADA3500 thermal power unit remote thermal load real-time online monitoring system is independently developed by Shenzhen Dongshen Intelligent Technology Co., Ltd., adopts B/S architecture, can be easily accessed through IE browser within the power company, and adopts dual-system in system structure. The hot standby operation mode ensures the reliability of the system and supports the storage of massive data. The goal is to implement the collection, transmission and remote monitoring of the thermal load data of the cogeneration unit in the province or region by the provincial or lower level grid company. The system capacity can exceed 500 substations.

1. Data collection function: real-time collection of temperature, pressure and flow rate of superheated steam at the boiler outlet of the heating unit, extraction steam flow and temperature and pressure parameters of the heating unit, flow, temperature and pressure parameters of the heat supply outlet of the thermal power plant, thermoelectric unit Power generation and power generation, total power generation and power generation of thermal power plants

2. Data processing functions: including range conversion, data fault tolerance, cold junction compensation, flow compensation, cumulative value calculation, etc., based on steam flow, pressure, temperature, enthalpy, entropy calculation.

3. Data storage function: The field acquisition data terminal has a strong data storage function. When the sampling period is less than 1 s and the storage period is less than 5 minutes, the data retention period is not less than 3 months.

4. Remote communication function: The collected data is transmitted to the power dispatch center through Ethernet, VPN, GPRS/CDMA communication.

5. Anti-interference ability index: common mode voltage ≥ 500V, common mode rejection ratio ≥ 90dB, differential mode voltage ≥ 60V, differential mode rejection ratio ≥ 60dB.

6. Acquisition accuracy: The accuracy of the analog input signal is ≥±0.1% (high level or current), ≥±0.2% (low level), and the average fault-free working time is ≥30000 hours.

System functions

1. Realize remote centralized monitoring of real-time operating parameters of thermal power units in the area;

2. High-precision data acquisition and transmission for heating and power generation operating parameters of the thermal power unit;

3. Real-time monitoring of the heating flow of the main outlet heating pipe of the thermal power plant and its temperature and pressure parameters;

4. Real-time monitoring of the exhaust steam flow and temperature and pressure parameters of each unit in the thermal power plant;

5. Real-time monitoring of the amount of power supplied by the thermal power plant to the grid and the amount of power generated by each unit's generators. ;

6. Real-time display of the thermoelectric ratio of each power plant, the whole plant heat supply and the whole plant power generation and real-time data collection.

7. The collection of real-time operating parameters of the thermal power plant and the display of the running curve: it is presented in various forms such as system structure diagram, running curve and data list.

8. Real-time data display, real-time data such as temperature, flow, pressure of each pipeline, and generator active power and electricity of the generator;

9. Thermoelectric ratio, energy saving ratio, coal consumption for power supply, total thermal efficiency, power generation capacity of “heat-set electricity”, and compliance with key data

10. Thermal power plant basic data management

11. Thermal power plant real-time and historical data management

12. Report Query and Statistics

Structure icon