Motor demagnetization reason
The cooling fan of the motor is abnormal, causing the motor to heat up.
The motor is not equipped with a temperature protection device
Ambient temperature is too high
Motor design is not reasonable
How to prevent demagnetization of permanent magnet motor? ? ?
Correct selection of permanent magnet motor power
Demagnetization is related to the power selection of permanent magnet motors.
Correct selection of the power of the permanent magnet motor can prevent or delay demagnetization.
The main reason for the demagnetization of permanent magnet synchronous motors is that the temperature is too high and the overload is the main cause of excessive temperature.
Therefore, when selecting the power of the permanent magnet motor, there must be a certain margin. According to the actual situation of the load, generally about 20% is suitable.
Avoid heavy load starting and frequent starting
The cage type asynchronous start synchronous permanent magnet motor tries to avoid direct start or frequent start of heavy load.
During the asynchronous starting process, the starting torque is oscillating. In the starting torque valley, the stator magnetic field is demagnetizing to the rotor pole.
Therefore, it is best to avoid overloading and frequent starting of asynchronous permanent magnet synchronous motors.