Dec 17, 2018 Leave a message

How to use the shake meter to determine the quality of a three-phase motor

How to use the shake meter to determine the quality of a three-phase motor

As electrical maintenance and repair personnel, the motor is the electrical equipment that they come into contact with, and it is also the most basic equipment. How do we use simple methods and measuring tools to detect the quality of the motor? We are mainly talking about three-phase motor.

“When the shaking table is normal, measure the phase-to-phase resistance value: connect the end buttons L and E of the shaking table to the binding posts of any two phases respectively, and shake the table slowly, the normal motor, the phase resistance should be around 0. And the resistance between any two phases should be close.

1

Under normal circumstances, in the case of determining that there is no problem with the power supply, the motor can not be started, use the multimeter to hit the ohm file, the red pen is connected to one terminal of the motor, and the black pen is connected to the other terminal of the motor. (When making measurement judgments, it is best to disconnect the power supply line to avoid interference.) If the resistance is measured (small resistance value), the coil is good; if the resistance is 0, the motor coil is shorted (phase-to-phase short circuit) . To measure the grounding, use a multimeter to test the motor at one end and the motor at the other end. If the resistance of the multimeter is zero, the motor is grounded (phase short).

In the case that the multimeter can't be confirmed, then we only use the shaker. Before using the shaker, we need to do the open and short circuit check of the shaker.

Open circuit check: Before the shake meter is not connected to the measured resistance, the terminal buttons L and E are suspended, and the handle is shaken to make the generator reach the rated speed of 2r/s (2 turns per second). The good pointer should be in the standard. The position of the ruler "∞".

Short-circuit check: Short-circuit the end buttons L and E and slowly shake the handle. The pointer should refer to the “0” position of the scale.

When the shaking table is normal, measure the resistance between the phases: connect the end buttons L and E of the shaking table to the binding posts of any two phases, and slowly shake the table. For normal motors, the phase resistance should be around 0, and The resistance between any two phases should be close.

Measuring and measuring the phase-to-earth resistance: connect the end button L of the shaker to the phase line terminal, and connect E to the motor housing. Shaking shake table resistance should be greater than 2MΩ, and should be greater than 0.5MΩ in supermarket environment, and the resistance between ground and ground should be greater than 5MΩ. If it is less than 0.5 Ω, it is an abnormal performance. Even if it can be used, it will not take long and the insulation is not enough.

Note: (1) If the resistance between the phase winding and the motor casing is less than 0.5MΩ:

1 The motor winding is poorly insulated in the motor casing. Continue to use the motor that is easily damaged, and the motor is prone to leakage.

2 The winding coil may have partially burned out the short circuit, continue to use, the motor has insufficient power, or the winding is completely burned out.

3 water content exceeds the standard and other reasons, it is easy to cause motor burnout.

(2) The shaking table is not allowed to shake the measured resistance for a long time, because the voltage of the shaking table is the rated voltage of the high voltage motor, and the long-term measurement has the danger of penetrating the motor insulation, causing short circuit or leakage.

(3) If the motor terminal has a connecting piece and the connecting piece needs to be disconnected, the speed regulating motor will be slightly different.


Send Inquiry