The structure and working principle of electric fan is the principle of magnetic dynamics. The main components of the electric fan are: AC motor. The working principle is: the current coil is rotated by force in a magnetic field. The form of energy conversion is: the electrical energy is mainly converted into mechanical energy, and due to the resistance of the coil, a part of the electrical energy is inevitably converted into internal energy. The power flow creates a rotating magnetic field to turn the rotor. There is a single-phase motor in the fan, which separates the single-phase alternating current from the alternating current with a 90-degree phase difference by starting a capacitor phase shift. The two phase alternating current is sent into two or four groups of motor coil windings respectively, and a rotating magnetic field is formed in the motor. The rotating magnetic field generates induced current in the motor rotor, and the magnetic field generated by the induced current is opposite to the rotating magnetic field, which is pushed and pulled into the rotating state by the rotating magnetic field.
Tube motor fan has high reliability, but it is still a mechanical device, in a long time of use, its speed may decline or even stop, so it is best to carry out real-time monitoring of the running state of the fan, to facilitate the timely discovery of problems. The alarm sensor can be used to give the alarm signal when the fan speed is below a certain threshold, and the output of the speed signal can realize the real-time monitoring of the fan speed.
The alarm signal output from the fan circuit has two states: "high level" and "low level". The meaning of the two levels is generally according to the positive logic system, with the high level representing "fault" and the low level representing "normal". The speed signal output from the fan circuit is usually in the form of pulses, with each wave head representing one turn of the fan. Such signals can be directly provided to the host for display through the data bus. The output speed signal of some fans is not the real speed of the fan, but a multiple of the speed. For example, two, four, or six pulses are generated per revolution, which must be processed to form the true speed signal of the fan. To determine whether the fan speed is the real speed or a multiple, use a tachometer to measure the actual speed and then compare it with the displayed data. The speed signal of the fan is usually output from the three-lead plug. The yellow and black of the three leads are +12V power supply and ground respectively, and the other color is the speed signal output wire. It should be noted that the third lead of some three-lead fans is not the speed signal output line, but the speed control signal line, through which the fan motor input speed control signal.